The GLS-OIR-CSM-EX-BATT is a battery-powered, passive infrared occupancy sensor designed for ceiling mount installation in small areas up to 500 square feet or 46.5 square meters. It communicates wirelessly with a Crestron control system via the infiNET EX® wireless network, allowing for quick installation without running any wires.
Passive Infrared Occupancy Sensing
Passive infrared (PIR) technology employs a highly sensitive specialized lens that divides the field-of-view into sensor zones. The sensor detects motion when a warm body passes between zones, achieving dependable motion detection with superior immunity to false triggering from vibrations, inanimate objects, or movement in an adjacent corridor. The detection sensitivity is adjustable for optimum performance. Timeout can be set anywhere from 30 seconds to 30 minutes to maintain occupied status during short periods of inactivity. A half mask and perforated mask are included to customize the coverage area.
Vacancy Only Mode with Grace Occupancy
The GLS-OIR-CSM-EX-BATT can be configured via the control system program to sense vacancy only. In this mode, the lighting and other equipment is shut off automatically when a room becomes vacant, but can only be turned on manually. If the lights turn off while someone is in the room, they can be turned back on by simply waving a hand within the 15 second grace period.
infiNET EX® Wireless Technology
Ultra-reliable infiNET EX wireless technology provides steadfast two-way RF communications throughout a residential or commercial structure without the need for physical control wiring. The GLS-OIR-CSM-EX-BATT communicates with a Crestron control system via an infiNET EX wireless gateway, and can function as part of a complete network of wireless sensors, lighting dimmers, motorized shades, thermostats, door locks, keypads, handheld remotes, and other devices.[1]
Ceiling Surface Mount Installation
The GLS-OIR-CSM-EX-BATT includes hardware for mounting to a typical drywall or drop-tile ceiling. When installed, it achieves a discreet appearance against a white ceiling, and may be painted to blend with other surfaces.
- Wireless ceiling mount occupancy sensor
- Passive infrared motion detection
- 360 degree, 500 square feet (46.5 m2) coverage
- Half mask and perforated mask included
- 10-year battery life using included 9 Volt lithium battery
- Control system integration via infiNET EX® wireless network
- Vacancy-only capability with grace occupancy
- Discreet, low-profile appearance
Sensing | ||
Sensor Technology | Passive Infrared | |
Coverage Area | 500 square feet; (46.5 square meters) |
|
Coverage Pattern | 360 degrees (half mask and perforated mask included) | |
Major Motion Area | 150 to 500 square feet; (13.9 to 46.4 square meters) |
|
Minor Motion Area | 0 to 150 square feet; (0 to 13.9 square meters) |
|
Power | ||
Battery | (1) Ultralife® U9VL-J-P 9 Volt 1200 mAh lithium disposable battery (included) | |
Battery Life | 10 years under normal operating conditions | |
Wireless | ||
RF Transceiver | infiNET EX 2-way RF, 2.4 GHz ISM Channels 11-26 (2400 to 2483.5 MHz), default channel 15; IEEE 802.15.4 compliant | |
Range (typical) | 50 ft (15 m) to gateway or nearest mesh network device(s), subject to site-specific conditions and individual device capabilities, range between floors or ceilings is limited to one level [1] | |
Gateway | Requires an infiNET EX gateway or Crestron Pyng control hub (sold separately) | |
Controls & Indicators | ||
SENSITIVITY | (1) Knob (behind cover), adjusts PIR sensitivity from low to high | |
TIMEOUT | (1) Knob (behind cover), adjusts timeout from 30 seconds to 30 minutes | |
TEST | (1) Pushbutton (behind cover) for test mode, setup, and battery condition | |
STATUS | (1) Red and (1) green LEDs for test mode, setup, and battery condition | |
Environmental | ||
Temperature | 32° to 104° F (0° to 40° C) | |
Humidity | 0% to 95% RH (non-condensing) | |
For indoor use only | ||
Construction | ||
Housing | Plastic, removable cover, white finish | |
Mounting | Ceiling surface mount, 3 inch (76 mm) screw spacing | |
Dimensions | ||
Height | 1.19 in (31 mm) | |
Diameter | 4.38 in (112 mm) | |
Weight | ||
Without Battery | 3.5 oz (98 g) | |
With Included Battery | 4.8 oz (135 g) | |
Compliance | ||
UL Listed, CE, IC, UL 60730-1, FCC Part 15 Class B digital device |
Infotabelle
Produktkennung
Artikelnummer | m0000L3R8K |
EAN | 0000063320978 |
GTIN | 00000063320978 |
Produktdetails
The GLS-OIR-CSM-EX-BATT is a battery-powered, passive infrared occupancy sensor designed for ceiling mount installation in small areas up to 500 square feet or 46.5 square meters. It communicates wirelessly with a Crestron control system via the infiNET EX® wireless network, allowing for quick installation without running any wires.
Passive Infrared Occupancy Sensing
Passive infrared (PIR) technology employs a highly sensitive specialized lens that divides the field-of-view into sensor zones. The sensor detects motion when a warm body passes between zones, achieving dependable motion detection with superior immunity to false triggering from vibrations, inanimate objects, or movement in an adjacent corridor. The detection sensitivity is adjustable for optimum performance. Timeout can be set anywhere from 30 seconds to 30 minutes to maintain occupied status during short periods of inactivity. A half mask and perforated mask are included to customize the coverage area.
Vacancy Only Mode with Grace Occupancy
The GLS-OIR-CSM-EX-BATT can be configured via the control system program to sense vacancy only. In this mode, the lighting and other equipment is shut off automatically when a room becomes vacant, but can only be turned on manually. If the lights turn off while someone is in the room, they can be turned back on by simply waving a hand within the 15 second grace period.
infiNET EX® Wireless Technology
Ultra-reliable infiNET EX wireless technology provides steadfast two-way RF communications throughout a residential or commercial structure without the need for physical control wiring. The GLS-OIR-CSM-EX-BATT communicates with a Crestron control system via an infiNET EX wireless gateway, and can function as part of a complete network of wireless sensors, lighting dimmers, motorized shades, thermostats, door locks, keypads, handheld remotes, and other devices.[1]
Ceiling Surface Mount Installation
The GLS-OIR-CSM-EX-BATT includes hardware for mounting to a typical drywall or drop-tile ceiling. When installed, it achieves a discreet appearance against a white ceiling, and may be painted to blend with other surfaces.
- Wireless ceiling mount occupancy sensor
- Passive infrared motion detection
- 360 degree, 500 square feet (46.5 m2) coverage
- Half mask and perforated mask included
- 10-year battery life using included 9 Volt lithium battery
- Control system integration via infiNET EX® wireless network
- Vacancy-only capability with grace occupancy
- Discreet, low-profile appearance
Sensing | ||
Sensor Technology | Passive Infrared | |
Coverage Area | 500 square feet; (46.5 square meters) |
|
Coverage Pattern | 360 degrees (half mask and perforated mask included) | |
Major Motion Area | 150 to 500 square feet; (13.9 to 46.4 square meters) |
|
Minor Motion Area | 0 to 150 square feet; (0 to 13.9 square meters) |
|
Power | ||
Battery | (1) Ultralife® U9VL-J-P 9 Volt 1200 mAh lithium disposable battery (included) | |
Battery Life | 10 years under normal operating conditions | |
Wireless | ||
RF Transceiver | infiNET EX 2-way RF, 2.4 GHz ISM Channels 11-26 (2400 to 2483.5 MHz), default channel 15; IEEE 802.15.4 compliant | |
Range (typical) | 50 ft (15 m) to gateway or nearest mesh network device(s), subject to site-specific conditions and individual device capabilities, range between floors or ceilings is limited to one level [1] | |
Gateway | Requires an infiNET EX gateway or Crestron Pyng control hub (sold separately) | |
Controls & Indicators | ||
SENSITIVITY | (1) Knob (behind cover), adjusts PIR sensitivity from low to high | |
TIMEOUT | (1) Knob (behind cover), adjusts timeout from 30 seconds to 30 minutes | |
TEST | (1) Pushbutton (behind cover) for test mode, setup, and battery condition | |
STATUS | (1) Red and (1) green LEDs for test mode, setup, and battery condition | |
Environmental | ||
Temperature | 32° to 104° F (0° to 40° C) | |
Humidity | 0% to 95% RH (non-condensing) | |
For indoor use only | ||
Construction | ||
Housing | Plastic, removable cover, white finish | |
Mounting | Ceiling surface mount, 3 inch (76 mm) screw spacing | |
Dimensions | ||
Height | 1.19 in (31 mm) | |
Diameter | 4.38 in (112 mm) | |
Weight | ||
Without Battery | 3.5 oz (98 g) | |
With Included Battery | 4.8 oz (135 g) | |
Compliance | ||
UL Listed, CE, IC, UL 60730-1, FCC Part 15 Class B digital device |